微波消解-石墨炉原子吸收光谱法测定植物染发剂中的铅镉铜 |
Determination of Lead,Cadmium and Calcium in Plant Hair Dye by GFAAS with Microwave Assisted Sample Digestion |
投稿时间:2010-08-12 修订日期:2010-09-08 |
DOI: |
中文关键词: 微波消解 石墨炉原子吸收光谱法 植物染发剂 Pb Cd Cu |
英文关键词:microwave assisted digestion GFAAS plant hair dye Pb Cd Cu |
基金项目:‘青岛大学创新型教学实验室’项目资助 |
|
摘要点击次数: 1745 |
全文下载次数: 218 |
中文摘要: |
建立了微波消解-石墨炉原子吸收光谱法测定植物染发剂中重金属铅、镉和铜的方法.采用L9(34)正交设计讨论了固液比、消解剂体积比、消解时间和消解压力对样品消解效果的影响,最佳的消解条件:固液比(g/mL)为1∶12,HNO3/H2O2(V/V)为4∶1,消解时间为5 min,消解压力1.5 MPa.在最佳微波消解条件下,进行了精密度实验、回收率实验,相对标准偏差为1.05%~3.35%,回收率为96.67%~105.43%.微波消解法处理植物染发剂样品,试剂用量少、消解完全、快速、简便,而且测定结果的精密度、准确度较好. |
英文摘要: |
A method for the determination of Pb Cd and Cu in plant hair dye by GFAAS with microwave assisted sample digestion has been set up, using a L9(34) orthogonal experiment. Effects of the ratio of the sample to digestion solution, ratio of digestion solution, digestion time and digestion pressure were studied. Optimum digestion conditions are: sample/solution (g/ml) 1∶12, HNO3/H2O2(V/V) 4∶1; digestion time, 5 min; and microwave pressure, 1.5 MPa. Under optimum digestion conditions, relative standard deviations were 1.05%~3.35%, average recoveries were 96.67%~105.43%. The results showed that the microwave digestion method is rapid and simple with low reagent consumption and complete digestion, and is of good accuracy and precision. |