微波消解石墨炉原子吸收法测定人发中的铅、镉
Determination of Lead and Cadmium in Human Hair by GFAAS with Microwave Digested Samples
投稿时间:2009-11-03  修订日期:2009-11-23
DOI:
中文关键词:  石墨炉原子吸收分光光度法,头发,铅,镉
英文关键词:GFAAS,Hair,Pb,Cd
基金项目:
作者单位E-mail
解蕾 青岛大学 化学化工与环境学院 应用化学系山东 青岛266071  
王亦军 青岛大学 化学化工与环境学院 应用化学系山东 青岛266071 yijunwangqdu@163.com 
傅瑛 青岛大学 化学化工与环境学院 应用化学系山东 青岛266071  
摘要点击次数: 1448
全文下载次数: 227
中文摘要:
      采用石墨炉原子吸收分光光度法(GFAAS)测定人发中的铅、镉含量.采用微波消解法消解样品,加入(NH4)2SO4+KH2PO4基体改进剂消除干扰,对消化剂种类、消解压力、仪器条件等进行了探索.方法简便、准确度高,Pb和Cd的平均回收率分别为101.8%和107.1%,相对标准偏差(RSD)为5.14%和6.80%,方法检出限Pb为9.53 ng/mL,Cd为0.78 ng/mL.
英文摘要:
      Pb and Cd in human hair were determined by graphite furnace atomic absorption spectrometry. The samples were digested by microwave with (NH4)2SO4 plus KH2PO4 as the modifier to eliminate the matrix interference. The type of digestant, digesting pressure and instrument parameter were studied. The method is simple and accurate. The average recoveries were 101.8% and 107.1% for Pb and Cd, respectively, and the relative standard deviations were 5.14% and 6.80%, and the detection limits were 9.53 ng/mL and 0.78 ng/mL.
HTML  查看全文  查看/发表评论  下载PDF阅读器