氢化物发生-原子荧光光谱法自动进样快速测定烟道灰中硒的应用研究 |
Application Study on Rapid Determination of Se in Chimney Ash with Automatic Sampling by Hydride Generation-Atomic Fluorescence Spectrometry |
投稿时间:2008-01-14 修订日期:2008-04-09 |
DOI: |
中文关键词: HG-AFS,快速测定,烟道灰,硒 |
英文关键词:HG-AFS,rapid determination,chimney ash,selenium |
基金项目: |
|
摘要点击次数: 1318 |
全文下载次数: 197 |
中文摘要: |
应用常规湿法消解与微波高压溶样2种不同的样品分解方法,研究了氢化物发生-原子荧光光谱法(HG-AFS)测定烟道灰中的硒.硒标准系列浓度在0.000~0.024 mg/L范围内与荧光强度具有良好的线性关系,相关系数为0.999 8. 方法检出限为0.007 5 mg/kg,相对标准偏差在0.87%~1.30%之间,加标回收率为98%~105% ,实验证实方法具备灵敏、快速、准确等优点.亦为回收利用烟道灰中的硒提供了科学依据. |
英文摘要: |
With two different sample decomposition methods of conventional wet digestion and microwave high pressure dissolution method, the determination of Se in chimney ash by HG-AFS is studied. Se standard concentration has good linear relationship with fluorescence intensity in the range of 0.000~0.024 mg/L,and corelative coefficient is 0.999 8. Detection limit of the method is 0.007 5 mg/kg, relative standard deviation is between 0.87%~1.30%,and recovery is 98%~105%.This method has the advcontages of high sensitivity,rapidity and accuracy.It provides scientific basis for recycling use of selenium in chimney ash. |