离子色谱法测定水样中氯离子的标准系列配制中测量不确定度评定
The Measurement Uncertainty Evaluation Determination of Chloride Ion in the Water Sample Preparation of a Series of Standards by Ion Chromatography
投稿时间:2006-11-30  修订日期:2007-02-02
DOI:
中文关键词:  不确定度,水样,氯离子,离子色谱法
英文关键词:uncertainty  water,chloride ion,Ion chromatography
基金项目:
作者单位
董道明 铜陵市环境监测站安徽 铜陵 244000 
孙军 铜陵市环境监测站安徽 铜陵 244000 
摘要点击次数: 1578
全文下载次数: 191
中文摘要:
      评定了离子色谱法测定水样中氯离子不确定度的来源, 如标准系列配制引起的不确定度、标准系列浓度-峰面积拟合直线引起的不确定度、样品稀释引起的不确定度,计算了不确定度分量及合成不确定度,扩展不确定度为5.7%.
英文摘要:
      The sources of measurements uncertainty on chloride ion in water by ion chromatography were analyzed, including the standard solution preparing, standard solution concentration -peak area fitting curve and diluting solution, and calculated the component and combined standard uncertainty. The expanded uncertainty was 5.7%.