离子色谱法测定水样中氯离子的标准系列配制中测量不确定度评定 |
The Measurement Uncertainty Evaluation Determination of Chloride Ion in the Water Sample Preparation of a Series of Standards by Ion Chromatography |
投稿时间:2006-11-30 修订日期:2007-02-02 |
DOI: |
中文关键词: 不确定度,水样,氯离子,离子色谱法 |
英文关键词:uncertainty water,chloride ion,Ion chromatography |
基金项目: |
|
摘要点击次数: 1578 |
全文下载次数: 191 |
中文摘要: |
评定了离子色谱法测定水样中氯离子不确定度的来源, 如标准系列配制引起的不确定度、标准系列浓度-峰面积拟合直线引起的不确定度、样品稀释引起的不确定度,计算了不确定度分量及合成不确定度,扩展不确定度为5.7%. |
英文摘要: |
The sources of measurements uncertainty on chloride ion in water by ion chromatography were analyzed, including the standard solution preparing, standard solution concentration -peak area fitting curve and diluting solution, and calculated the component and combined standard uncertainty. The expanded uncertainty was 5.7%. |