用苯胺作标准分析硝基苯类化合物
Determimation of Nitrobenzene with Aniline Standard
投稿时间:2005-09-21  修订日期:2005-11-21
DOI:
中文关键词:  苯胺  硝基苯  分光光度法
英文关键词:aniline  nitrobenzene  spectrophotometry
基金项目:
作者单位
夏冬前 泰兴市环境监测站, 江苏, 泰兴, 225400 
吴新圣 泰兴市环境保护局, 江苏, 泰兴, 225400 
摘要点击次数: 1118
全文下载次数: 6
中文摘要:
      还原偶氮比色法分析硝基苯,分析结果受锌渣和慢速滤纸吸附系统误差的影响,结果偏低.用苯胺作标准,可去除硝基苯前处理还原中吸附产生的系统误差,提高硝基苯分析结果的可比性、准确性.
英文摘要:
      The data of nitrobenzene was lower when determination by nitrobenzene-reduction with Zine-N(1-Naphthyl) ethylene diamine dihydrochloride spectrophotometric method,because of absorption of zinc sediment and filter paper.In this paper,the system error of the process of reduction and filtration,the accuracy and comparability were improved by standard analysis of aniline.
HTML  查看全文  查看/发表评论  下载PDF阅读器