原子吸收光谱法测定镉镍电池浸渍液中硅
Atomic Absorption Spectrometry to Measure the Content of Silicon in Impregnating Solution of Cd-Ni Batteries
投稿时间:2002-11-12  修订日期:2003-01-20
DOI:
中文关键词:  一氧化二氮乙炔火焰  原子吸收光谱  镉镍电池浸渍液  
英文关键词:nitrous oxide-ethyne flame  atomic absorption spectrophotometer  Cd-Ni batteries impregnating solution  silicon
基金项目:
作者单位
薛光荣 中国航天科技集团公司空间电源研究所, 上海, 200233 
摘要点击次数: 726
全文下载次数: 2
中文摘要:
      提出用一氧化二氮乙炔火焰原子吸收光谱法测定镉镍电池浸渍液中硅含量.方法具有良好的灵敏度,干扰少,重现性好.硅量在5~50μg/mL范围内与吸光度呈良好的线性关系.其相对标准偏差均为1.0%;标准加入回收率在97.0%~103.0%范围内,适用于镉镍电池浸渍液中硅的分析.完全达到了实验室分析质量控制的要求.
英文摘要:
      The application of nitrous oxide-ethyne flame atomic absorbing spectral method to measure the content of silicon in Cd-Ni batteries impregnating solution is studied. The optimum measuring conditions for silicon and potency in which a fine liner range presents is introduced, and makes a synthetic consideration to interference factors. The method has the advantages of high sensitivity,And this method is proved, to be simple operation, easy master, short analyzing cycle, less interference and good in selectivity and reappearance. The relative standard deviations are all less than 1.0% in six sample measures, and the standard adding recovery is the range of 97%~103% in six sample measures the practice shows that the method is fully suited to measure the silicon content in Cd-Ni batteries impregnating solution. The proposed method was proved to be a useful instrument analytical technique in nitrous oxide-ethyne flame absorbing spectral method.
HTML  查看全文  查看/发表评论  下载PDF阅读器