| 吸附溶出伏安法测定血浆和尿液中的尿酸 |
| Determination of Uric Acid in Human Plasma and Urine by Adsorptive Stripping Voltammetry |
| 投稿时间:1997-04-23 修订日期:1997-07-14 |
| DOI: |
| 中文关键词: 尿酸 吸附 溶出伏安法 血浆 尿液 |
| 英文关键词:uric acid adsorption stripping voltammetry urine plasma |
| 基金项目:陕西省教委专项科研基金 |
|
| 摘要点击次数: 753 |
| 全文下载次数: 3 |
| 中文摘要: |
| 在Britton-Robinson缓冲体系中(pH7.50),研究了尿酸的伏安行为.实验表明,尿酸在悬汞电极上具有吸附行为,并于-0.08V(vsSCE)产生灵敏的峰电流.尿酸浓度在2.0×10-8~1.0×10-5mol/L范围内与吸附峰电流成线性关系,检出限可达1.0×10-8mol/L.该法可用于尿液和血浆中尿酸的测定,回收率为95~105%. |
| 英文摘要: |
| The voltammetric behavior of uric acid on hanging mercury electrode has been investigated in Britton-Robinson buffer solution(pH7.50).It has been found that uric acid can produce a sensitive adsorptive current at -0.08V.The adsorptive peak current is linear with uric acid concentration in the range of 2.0×10-8~1.0×10-5 mol/L,and the detection limit is 1.0×10-8 mol/L.The method can be used for determinating uric acid in human urine and plasma.The recovery is 95%~105%. |