电感耦合等离子体质谱法测定黄沙土壤中铅同位素比 |
Determination of Lead Isotopic Ratios in Original KOSA Soils by Inductively Coupled Plasma Mass Spectrometry |
投稿时间:1995-11-26 修订日期:1996-02-09 |
DOI: |
中文关键词: 铅 同位素比 黄沙原土 ICP—MS ICP—AES 土壤分析 |
英文关键词:Lead Isotope ratio Original KOSA soil Inductively coupled plasma mass spectrometry Inductively coupled plasma atomic emission spectrometry Soil analysis |
基金项目: |
|
摘要点击次数: 927 |
全文下载次数: 3 |
中文摘要: |
用电感耦合等离子体质谱法(ICP-MS)测定了5个黄沙原土样品中铅同位素比207Pb/206Pb、208Pb/206Pb,样品来自被认为是黄沙气溶胶源地区,为了使铅同位素测量中质量偏差和漂移减至最少,在样品中加入了铊标准溶液,测量205Tl/203Tl比,校正质量数差别选择的影响。同时,采用ICP-MS和电感耦合等离子体原子发射光谱法(ICP-AlS)测定了随粒径变化样品中12种元素浓度的变化。 |
英文摘要: |
Five original KOSA soils,collected in the locations of being thought to be the origins of KOSA aerosol in China,were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) to determine the lead isotope ratios 207Pb/206Pb and 208Pb/206Pb.Tominimize mass bias and drift in Pb isotope measurement,the mass discrimination correction,based upon the addition of thallium to the samples and measurement of 205Tl/203Tl ratio,was used.At the same the, concentrations of 12 elments were determined as a function of particle-size by ICP-MS and induedvely coupled plasma atomic emission spectrometry (ICP-AES). |
HTML 查看全文 查看/发表评论 下载PDF阅读器 |