novAA400P石墨炉原子吸收光谱仪常见故障分析、处理和日常维护要求 |
Common Failure Analysis, Treatment and Routine Maintenance Requirements of novAA400P GFAAS |
投稿时间:2018-09-13 修订日期:2018-10-11 |
DOI:10.16495/j.1006-3757.2018.04.011 |
中文关键词: 石墨炉 原子吸收 故障 维护 |
英文关键词:graphite furnace atomic absorption fault maintenance |
基金项目: |
|
摘要点击次数: 418 |
全文下载次数: 12 |
中文摘要: |
对novAA400P石墨炉原子吸收光谱仪常见故障进行了分析总结,并结合应用实践给出了处理方法,可以快速准确地进行故障的处理,保证检测工作的顺利进行,同时对石墨炉原子吸收的日常维护进行了介绍. |
英文摘要: |
The common troubles of novAA400P graphite furnace atomic absorption spectrometer are analyzed and summarized, the treatment methods are given in combination with the application practice, which can deal with the problems quickly and accurately, ensure the smooth progress of the detection work, and explain the daily maintenance of graphite furnace atomic absorption spectrometer. |