硝酸镉中铁铜锌铅的FAAS快速分析测试技术 |
Quick Determination of Iron, Copper, Zinc and Lead in Cadmium Nitrate by Flame Atomic Absorption Spectroscopy |
投稿时间:2007-11-02 修订日期:2007-11-30 |
DOI: |
中文关键词: FAAS法(原子吸收光谱法),硝酸镉,铁,铜,锌,铅,快速分析测试技术 |
英文关键词:FAAS,cadmium nitrate,Iron,Copper,Zinc,Lead,determination of analysis |
基金项目: |
|
摘要点击次数: 1347 |
全文下载次数: 176 |
中文摘要: |
运用FAAS快速分析硝酸镉中铁、铜、锌、铅含量,建立了铁、铜、锌、铅的共振线,灯电流,酸性介质等最佳实验条件.显示出该方法具有很好的灵敏度和材料重现性,具有方法步骤简单、操作容易、干扰少等特点.测定样品铁、铜、锌、铅含量的相对标准偏差均小于1.0%(n=10).标准加入回收率均在97.0%~98.5% 范围内.适用于硝酸镉中铁、铜、锌、铅的含量控制分析和样品系统分析. |
英文摘要: |
Utilizing FAAS the quick determine of Iron, Copper,Zinc and Lead in cadmium nitrate was described. The deviation RSD<1.0% comparing to standard value. The standard adding recovery is in the range of 97.0%~98.5%. The method was fully suitable to the control of Iron,Copper,Zinc and Lead in cadmium nitrate. |