用N2O-C2H2火焰原子吸收光谱法测定膨胀合金中硅 |
Measurement of Silicon in the Alloy Expands by N2O-C2H2 Flame Atomic Absorption Spectrometer |
投稿时间:2006-08-21 修订日期:2006-09-22 |
DOI: |
中文关键词: N2O-C2H2 原子吸收光谱法 膨胀合金 硅 |
英文关键词:N2O-C2H2 flame atomic absorption spectrometer the alloy expands silicon |
基金项目: |
|
摘要点击次数: 917 |
全文下载次数: 4 |
中文摘要: |
采用N2O-C2H2火焰原子吸收光谱法测定膨胀合金中硅.建立了硅的最佳测定条件,并在样品测定中对干扰因素进行了综合考虑.实验表明:该方法具有灵敏度高、选择性好,操作简便、容易掌握、分析周期短等优点.其相对标准偏差均小于1.0%(n=6).标准加入回收率均为97.0%~99.0%(n=6)范围内.可以作为检测膨胀合金中硅含量的一种手段. |
英文摘要: |
The application of N2O-C2H2 flame Atomic absorption spectrometer to measure of silicon in the alloy expands is studied.This paper introduces the optimum measuring conditions for silicon and potency in which a fine liner range presents.And makes a synthetic consideration to interference factors.The method has the advantages of high sensitivity,less interference and good in selectivity and reappearance.The relative standard deviations are all less than 1.0%(n=6)in six sample measures,and the standard adding recovery is in the range of 97.0%~99.0%(n=6),the practice shows that the method is fully suitable to measure the silicon in the alloy expands. |
HTML 查看全文 查看/发表评论 下载PDF阅读器 |